PDU sockets, Power Distribution Unit sockets China manufacturer
PDU Sockets : POWER DISTRIBUTION UNIT Sockets.
(general the PDU are viewed as RPDU:RACK- POWER DISTRIBUTION UNIT) As the manufacturer/exporter of low & medicum voltage electric equipment, we have developed the new series of PDU sockets and socket modulars, which is one of power distribution products for the usage of distribution unit, power protection, electrical distribution systems, power distribution box,power distribution unit,power distribution solutions. We have the strong mould design and production ability to support the material of the our Industrial plugs & sockets, Power Distribution Unit Sockets--PDF Sockets,and other kinds series,like:Desk Sockets, Floor Sockets/Ground Sockets,Ceiling Sockets.
Defination of PDU Sockets
Large industrial units are used for taking high voltage and amperage and reducing it to more common and useful levels, for example from 220V 30A single phase to multiple 110V 15A or 110V 20A plugs. They are used incomputer data centers, stage shows, by DJs, and in other electrically intensive applications. Some have features like remote monitoring or control down to the individual plug. A 240 volt circuit (120 volts x2 plus neutral and ground) has two legs at 120 volts. A distro switches and provides circuit protection for the taps off of the phases/legs. A PDU allows for a solidly bonded neutral, and a safe grounding system. PDU also refers to what amounts to a well-constructed power strip suitable for datacenter use. Two basic varieties distinguished by the type of input power are common: single-phase and three-phase. The output power (i.e. the power to the load device) is always single-phase, however. In the case of a three-phase PDU, each of the three phases appears individually on every third receptacle. PDUs can be dumb -- meaning that they have no instrumentation and are not manageable, or they can be metered -- meaning that they are equipped with a display that shows current load on each phase, or they can be switched -- meaning that some or all of their receptacles can be individually switched on or off remotely. One of the challenges in selecting PDUs for a datacenter application is to balance the relatively high cost of a switched PDU versus the relatively low cost of a dumb PDU, but then managing the risk that the phases may become unbalanced, or devices may be unexpectedly plugged in, possibly tripping a circuit breaker.
Specifications of PDU Sockets made by Ningbo-Electric-Pneumatic
(1) Types for Different Countries:France Type PDU, UK Type PDU, Italy Type PDU, US Type PUD Socket, IEC Type PDU sockets, Omnipotence Type, National Standard Type PDU socket... (2) Installation Direction: vertical 19" mountable units / horizontal 19" mountable power distribution units; (3) ll functional modules are adopted PC/ABS alloy ,hot change temperature reach to above 120℃ ,fire-retardant haracteristic accords with UL94-V0 standard. (4) Certifications for our PDU Sockets Supplier : GS、CE、UL、3C; ----------------------------------------------------
UK Power PDU Sockets, 19'' cabinet,6 way horizontal Distribution Unit
Model: PB2L-06S Socket/Outlet Standard : BS1363 Outlet QTY: 6 way Power Input Style : Left end single input style Brackets Installation Style: Frontal installation style Cable plug : BS1363 Control functions : Switch Protection functions: No Shell colour & Material: Black; Aluminium modular design: Cable specification: 3*1.5mm2*3M; Standard 3 metre power cord: Electrical Rating: 13A 250VAC Maximum load current: 13A Maximum load capacity : 4KW Size of this UK PDU socket: L*W*H: 482.6*44.4*62mm Relative humidity for PDU: 10-90%
UK power distribution units are the standard choice in sever and networking 19” racks connecting directly to the targeted equipment, they are available as 13A to UK power or C19 plug. All PDU products of Betterbell are modularized,customer can choose the relative modules and power input cables. All functional modules are adopted PC/ABS alloy ,hot change temperature reach to above 120℃ ,fire-retardant characteristic accords with UL94-V0 standard.
----------------------------------------------------
UK 19” cabinet Power PDU, 7 way horizontal Power Distribution Unit.
Model:PB1L-07I Socket/Outlet Standard BS1363 Outlet QTY 7 way Power Input Style Left end single input style Brackets Installation Style Frontal installation style Cable plug for UK PDU sockets BS1363 Control functions Single power indicator(Neon indicator) Protection functions No Shell colour & Material Black; Aluminium modular design Cable specification 3*1.5mm2*3M; Standard 3 metre power cord PDU Electrical Rating 13A 250VAC Maximum load current 13A Maximum load capacity 4KW Size of PUD socket L*W*H 482.6*44.4*62mm Relative humidity 10-90%
UK power distribution units are the standard choice in sever and networking 19” racks connecting directly to the targeted equipment, they are available as 13A to UK power or C19 plug. All PDU products of Betterbell are modularized,customer can choose the relative modules and power input cables. All functional modules are adopted PC/ABS alloy ,hot change temperature reach to above 120℃ ,fire- retardant characteristic accords with UL94-V0 standard. ----------------------------------------------------
China 10A Power PDU, 19” cabinet Distribution Unit, 7 way PDU
Model PC2L-07IS Socket/Outlet Standard GB1002/10A Outlet QTY 7 way Power Input Style Left end single input style Brackets Installation Style Frontal installation style Cable plug GB1002/10A Control functions Neon indicator; Master switch Protection functions No Shell colour & Material Black; Aluminium modular design Cable specification 3*1.5mm2*3M; Standard 3 metre power cord Electrical Rating 10A 250VAC Maximum load current 16A Maximum load capacity 4KW Size L*W*H 482.6*44.4*62mm Relative humidity 10-90%
China 10A power distribution units are the standard choice in sever and networking 19” racks connecting directly to the targeted equipment. All PDU products of Betterbell are modularized,customer can choose the relative modules and power input cables. All functional modules are adopted PC/ABS alloy ,hot change temperature reach to above 120℃,fire- retardant characteristic accords with UL94-V0 standard.
----------------------------------------------------
China 10A Power PDU,19” cabinet,8 way Distribution Units
Model PC1L-08I Socket/Outlet Standard GB1002/10A Outlet QTY 8 way Power Input Style Left end single input style Brackets Installation Style Frontal installation style Cable plug GB1002/10A Control functions Single power indicator(Neon indicator) Protection functions No Shell colour & Material White; Aluminium modular design Cable specification 3*1.5mm2*3M; Standard 3 metre power cord Electrical Rating 10A 250VAC Maximum load current 16A Maximum load capacity 4KW Size L*W*H 482.6*44.4*62mm Relative humidity 10-90%
China 10A power distribution units are the standard choice in sever and networking 19” racks connecting directly to the targeted equipment. Ningbo Manufacturer,supplier and exporter of PDU sockets.
----------------------------------------------------
1China 16A Power PDU,9” cabinet, 8 way Distribution Units
Model PC3L-08C Socket/Outlet Standard GB1002/16A Outlet QTY 8 way Power Input Style Left end single input style Brackets Installation Style Frontal installation style Cable plug GB1002/16A Control functions over-current protection Protection functions No Shell colour & Material White; Aluminium modular design Cable specification 3*1.5mm2*3M; Standard 3 metre power cord Electrical Rating 16A 250VAC Maximum load current 16A Maximum load capacity 4KW Size L*W*H 482.6*44.4*62mm Relative humidity 10-90%
----------------------------------------------------
IEC320 C13 Power PDU,19” cabinet , 8 way horizontal Power Distribution Unit
Model PE2L-08S Socket/Outlet Standard IEC320 C13 Outlet QTY 8 way Power Input Style Left end single input style Brackets Installation Style Frontal installation style Cable plug IEC320 C20 Control functions Protection functions Switch Shell colour & Material White; Aluminium modular design Cable specification 3*1.5mm2*3M; Standard 3 metre power cord Electrical Rating 10A 250VAC Maximum load current 10A Maximum load capacity 4KW Size L*W*H 482.6*44.4*62mm Relative humidity 10-90%
IEC320 C13 power distribution units are the standard choice in sever and networking 19” racks connecting directly to the targeted equipment, they are available as 10A to IEC320 C14 plug. All PDU products of Betterbell are modularized,customer can choose the relative modules and power input cables. All functional modules are adopted PC/ABS alloy ,hot change temperature reach to above 120℃,fire-retardant characteristic accords with UL94-V0 standard. ----------------------------------------------------
France NF C61 Power PDU,19” cabinet, 8 ways distribution units
Model PF1L-08I Socket/Outlet Standard French NFC 61-314 Outlet QTY 8 way Power Input Style Left end single input style Brackets Installation Style Frontal installation style Cable plug DIN49441 Control functions Single power indicator(Neon indicator) Protection functions No Shell colour & Material White; Aluminium modular design Cable specification 3*1.5mm2*3M; Standard 3 metre power cord Electrical Rating 16A 250VAC Maximum load current 16A Maximum load capacity 4KW Size L*W*H 482.6*44.4*62mm Relative humidity 10-90%
French power distribution units are the standard choice in sever and networking 19” racks connecting directly to the targeted equipment, they are available as 16A to France power or C19 plug. All PDU products of Betterbell are modularized,customer can choose the relative modules and power input cables. All functional modules are adopted PC/ABS alloy ,hot change temperature reach to above 120℃,fire-retardant characteristic accords with UL94-V0 standard. We are the Chine manufacturer/exporter/supplir of PDU sockets, Power Distribution Units Sockets. ----------------------------------------------------
Germany DIN49440 Power PDU,19” cabinet, 8 way power distribute unit sockets
Model PG1L-08I Socket/Outlet Standard DIN49440 Outlet QTY 8 way Power Input Style Left end single input style Brackets Installation Style Frontal installation style Cable plug DIN49441 Control functions Single power indicator(Neon indicator) Protection functions No Shell colour & Material White; Aluminium modular design Cable specification 3*1.5mm2*3M; Standard 3 metre power cord Electrical Rating 16A 250VAC Maximum load current 16A Maximum load capacity 4KW Size L*W*H 482.6*44.4*62mm Relative humidity 10-90%
Germany DIN power distribution units are the standard choice in sever and networking 19” racks connecting directly to the targeted equipment, they are available as 16A to Germany power or C19 plug. All PDU products of Betterbell are modularized,customer can choose the relative modules and power input cables. All functional modules are adopted PC/ABS alloy ,hot change temperature reach to above 120℃,fire-retardant characteristic accords with UL94-V0 standard. -----------------------------------------
USA PDU Sockets, 19” cabinet, 8 way PDU distribution units.
Model PU*L-07IS Socket/Outlet Standard IEC60906 Outlet QTY 8 way Power Input Style Left end single input style Brackets Installation Style Frontal installation style Cable plug IEC60906 Control functions LED indicator; Master switch Protection functions No Shell colour & Material Black; Aluminium modular design Cable specification 3*1.5mm2*3M; Standard 3 metre power cord Electrical Rating 15A 125VAC Maximum load current 15A Maximum load capacity 4KW Size L*W*H 482.6*44.4*62mm Relative humidity 10-90%
USA power distribution units are the standard choice in sever and networking 19” racks connecting directly to the targeted equipment. All PDU products of Betterbell are modularized,customer can choose the relative modules and power input cables. All functional modules are adopted PC/ABS alloy ,hot change temperature reach to above 120℃,fire- retardant characteristic accords with UL94-V0 standard.
-----------------------------------------
USA Power PDU, 19” Rack Mount, 8 ways power distribution units sockets
Model PU1L-08I Socket/Outlet Standard IEC60906 Outlet QTY 8 way Power Input Style Left end single input style Brackets Installation Style Frontal installation style Cable plug IEC60906 Control functions Neon indicator; Protection functions No Shell colour & Material Black; Aluminium modular design Cable specification 3*1.5mm2*3M; Standard 3 metre power cord Electrical Rating 10A 250VAC Maximum load current 10A Maximum load capacity 2.5KW Size L*W*H 482.6*44.4*62mm Relative humidity 10-90%
-----------------------------------------
Universal Power PDU,19” cabinet, 8 ways power distribution units sockest
Model PW1L-08I Socket/Outlet Standard GB2099.3 Outlet QTY 8 way Power Input Style Left end single input style Brackets Installation Style Frontal installation style Cable plug GB1002/16A Control functions LED; Protection functions No Shell colour & Material Black; Aluminium modular design Cable specification 3*1.5mm2*3M; Standard 3 metre power cord Electrical Rating 10A 250VAC Maximum load current 16A Maximum load capacity 4KW Size L*W*H 482.6*44.4*62mm Relative humidity 10-90%
Universal 10A power distribution units are the standard choice in sever and networking 19” racks connecting directly to the targeted equipment. All PDU products of Betterbell are modularized,customer can choose the relative modules and power input cables. -----------------------------------------
Italy(Universal) Power PDU, 19” Cabinet ,6 way power distribution units socket manufacturer in Ningbo, China
Model PY4L-06M Socket/Outlet Standard CEI23-50(IEC60884-1) Outlet QTY 6 way Power Input Style Left end single input style Brackets Installation Style Frontal installation style Cable plug CEI23-50(IEC60884-1) Control functions Single power indicator(Neon indicator) Protection functions Indicator+Switch+Breaker Shell colour & Material White; Aluminium modular design Cable specification 3*1.5mm2*3M; Standard 3 metre power cord Electrical Rating 10A 250VAC Maximum load current 10A Maximum load capacity 4KW Size L*W*H 482.6*44.4*62mm Relative humidity 10-90%
Italy (universal) power distribution units sockets are the standard choice in sever and networking 19” racks connecting directly to the targeted equipment, they are available as 16A to Italy plug. All PDU products of Betterbell are modularized,customer can choose the relative modules and power input cables. All functional modules are adopted PC/ABS alloy ,hot change temperature reach to above 120℃,fire-retardant characteristic accords with UL94-V0 standard. Ningbo,China supplier/factory of Power Distribution Unit sockets China manufacturer
|